TROUBLESHOOTING ~ ACORN AQUA WATER COOLERS

If you have any problems with your Aqua Water Cooler, please refer in the first instance to the manual supplied with the water cooler. The following extract may be of immediate help:
 
START UP:
 1)   Before assembling bottom cover to drinking fountain, but after thoroughly flushing the supply line and connecting it
       to the fixture, turn on building water supply and check all connections for leaks.
2)    Air within the drinking fountain or the structure supply piping will cause an irregular bubbler outlet stream until purged
       out by incoming water. Covering the bubbler with a clean cup (or similar object) is recommended when first activating
       drinking fountain to prevent excessive splashing. Depress a side or front push bar until steady water stream is achieved
3)    If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the underside of the
       fixture in the knee clearance area up to the flow regulator. Turning clockwise will increase flow and turning counter-
       clockwise will decrease flow.
4)    Recheck all water and drain connections with water flowing through system.
5)    Assemble bottom cover to drinking fountain with screws furnished.
 
TROUBLE SHOOTING:
1.    No Water Flow
         a. Check water main supply – open.
         b. Inspect stop (by others) – open and no debris.
         c. Inspect in-line strainer for debris – clean.
         d. Replace valve cartridge.
2.   Water Drips / Will Not Shut Off
         a. Replace valve cartridge
.
 

Return to Aqua product selection page                                          View Apinox standard (uncooled) drinking fountains